uProcess™ Automated Pumps, Valves and Sensors

The LabSmith breadboard-based uProcess™ automated syringe pumps, valves, pressure and temperature sensors are part of the uProcess microfluidics automation system of software and hardware products which provides simple, straightforward automated routing of microfluidic volumes.

uProcess automated devices work together with CapTite™ microfluidic interconnect products to make it easy to build and rebuild micro- and nano-fluidic circuits. All products are inter-compatible and quick to assemble, taking the hassle out of fluid routing and control.

SPS01 Syringe PumpSPS01 Programmable Syringe Pumps deliver volumes up to 100 microliters, with resolution as low as 2 nanoliters. The pump body design allows syringes to be easily removed and replaced, providing a wide range of volumes with a single pump.
AV201 automated valveAutomated Selector Valves provide 2-position, 3, 4 or 6-port switching, with near-zero dead volumes and low swept volumes and a switching time at just 0.4 seconds, and 8-position, 9 port selector valves.
Miniature pressure sensors fit into any CapTite port to measure fluid pressure for monitoring or control with very low dead volume.


Temperature sensors. K-type bare or insulated thermocopuples that fits to the 4AM analog sensor module.


Heater/cooler units. Peltier elements for cooling or heating. Connects to the 4PM 15W miniature power driver module.


uProcess Software provides a simple interface for configuring and controlling uProcess pumps and valves and for creating automated processes for coordinated control.
uPB breadboards provides a compact, stable mechanical mounting platform for uProcess devices and microfluidic chips, tied together with CapTite flow routing and interconnect components.

All uProcess devices are connected through a common bus on the uPB Breadboard to an interface box, communicating with the software through a USB interface. One control interface can sequence and coordinate more than 30 devices, and breadboards can hold 5, 8 or 12 devices each.

Labsmith uProcess Brochure

View as List Grid

8 Items

per page
Set Descending Direction
  1. Automated 3 port Valve

    From €774.14

    To €819.68

    AV201 Automated Valves.
    Two-position three-port automated valves. Available for 360um capillary, 1/32" tubing or 1/16" tubing. Requires a 4VM valve manifold and EIB controller for communicating with PC. Connects to capillary or tubing via one-piece fitting (not included). Learn More
  2. uPS Pressure Sensor
    €193.53
    Miniature pressure sensors for the line of uProcess™ flow control devices. The uPS can be installed in any LabSmith CapTite™ fitting and is ideal for accurate, low-dead volume pressure monitoring and control of microfluidic systems. Learn More
  3. Automated 4 port Valve

    From €887.98

    To €944.91

    AV202 Automated Valve
    Two-position four-port automated valve with "II" shaped flow pattern. Available for 360um or 1/32" tubing size. Requires a 4VM valve manifold and EIB controller for communicating with PC. Connects to capillaries/tubing via one-piece fittings (not included).
    Learn More
  4. uTE Thermal-Electric Module
    €193.53
    LabSmith uTE-series thermal-electric module.
    The uTE module is used for heating or cooling your microfluidic application. The module can be coupled with a uTS temperature sensor for precision thermal monitoring and control using LabSmith's uProcess software.
    The uTE-series thermal-electric modules require a 4PM01 Power Manifold and EIB200 uprocess interface. A uTS temperature sensor is recommended for monitoring and control of the uTE module.
    Learn More
  5. uTS Temperature sensors

    From €125.23

    To €136.61

    LabSmith uTS-series temperature sensors.
    The uTS can be used alone for on-chip or in-fluid temperature monitoring, or with the uTE-series thermal-electric module for complete temperature control. Controlled using the LabSmith uProcess software suite or LabView, the uTS and uTE precision thermal management products are a perfect compliment to LabSmith's complete monitoring and control of microfluidic systems.
    The uTS-series temperature sensors require a 4AM01 sensor manifold and EIB200 USB interface.
    • Temperature range: -150 – 200° C
    • Sensor type: K-type thermocouple
    • Accuracy: 0.5° C
    • Precision: 0.001° C
    Learn More
  6. uProcess Electrophoresis Power Module
    €597.68
    Programmable single-channel 300V high-voltage module for the uProcess system.
    Learn More
  7. Syringe Glass & Plunger Set
    €148.00
    Syringe glass and plunger set SG-XXX-C360 connects to 360 um OD tubing using C360-100. SG-080-T116 connects to 1/16" OD tubing using T116-100. Connects to one piece fitting (not included). Learn More
  8. uProcess Breadboard

    From €102.46

    To €364.30

    Breadboard for mounting uProcess devices. Available with 5 or 8 device connections. Material: Fiberglass Learn More
View as List Grid

8 Items

per page
Set Descending Direction